Skip to Content
MilliporeSigma
  • Polychlorinated biphenyls-containing electrical insulating oil contaminated soil treatment with calcium and magnesium peroxides.

Polychlorinated biphenyls-containing electrical insulating oil contaminated soil treatment with calcium and magnesium peroxides.

Chemosphere (2010-12-15)
Anna Goi, Marika Viisimaa, Marina Trapido, Rein Munter
ABSTRACT

Calcium and magnesium peroxides were applied for the treatment of soil contaminated by polychlorinated biphenyls-containing electrical insulating oil (Aroclor 1016). The removal of PCB-containing electrical insulating oil was achieved with the addition of either calcium peroxide or magnesium peroxide alone and dependent on dosages of the chemical. A 21-d treatment of 60% watered soil with the moderate addition (chemical/oil weight ratio of 0.005/1) of either calcium peroxide or magnesium peroxide resulted in nearly complete (96 ± 2%) oil removal, unsubstantial increase in soil pH and almost no changes in oxygen consumption and dehydrogenase activity, making it suitable for the soil decontamination.

MATERIALS
Product Number
Brand
Product Description

Supelco
Aroclor 1016 solution, certified reference material, 1000 μg/mL in isooctane