Skip to Content
MilliporeSigma
  • Development and Application of a High-Resolution Imaging Mass Spectrometer for the Study of Plant Tissues.

Development and Application of a High-Resolution Imaging Mass Spectrometer for the Study of Plant Tissues.

Plant & cell physiology (2015-06-13)
Katsutoshi Takahashi, Toshiaki Kozuka, Aya Anegawa, Akira Nagatani, Tetsuro Mimura
ABSTRACT

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) or imaging mass spectrometry (imaging MS) has been a powerful tool to map the spatial distribution of molecules on the surface of biological materials. This technique has frequently been applied to animal tissue slices for the purpose of mapping proteins, peptides, lipids, sugars or small metabolites to find disease-specific biomarkers or to study drug metabolism. Recently, it has also been applied to intact plant tissues or thin slices thereof using commercial mass spectrometers. The present work is concerned with the refinement of MALDI/laser desorption/ionization (LDI)-Fourier transform ion cyclotron resonance (FTICR)-MS incorporating certain specific features namely, ultra-high mass resolution (>100,000), ultra-high molecular mass accuracy (<1 p.p.m.) and high spatial resolution (<10 µm) for imaging MS of plant tissues. Employing an in-house built mass spectrometer, the imaging MS analysis of intact Arabidopsis thaliana tissues, namely etiolated seedlings and roots of seedlings, glued to a small transparent ITO (indium tin oxide)-coated conductive glass was performed. A matrix substance was applied to the vacuum-dried intact tissues by sublimation prior to the imaging MS analysis. The images of various small metabolites representing their two-dimensional distribution on the dried intact tissues were obtained with or without different matrix substances. The effects of MALDI matrices on the ionization of small metabolites during imaging MS acquisition are discussed.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Hexane, anhydrous, 95%
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Hexane, JIS 1000, ≥96.0%, for residue analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
Hexane, JIS 300, ≥96.0%, for residue analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
Hexane, SAJ first grade, ≥95.0%
Sigma-Aldrich
Hexane, ≥96.0%, suitable for residual phthalate analysis
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Hexane, JIS special grade, ≥96.0%
Sigma-Aldrich
Acetonitrile, for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, for chromatography
Sigma-Aldrich
Hexane, for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Hexane, suitable for HPLC