Skip to Content
MilliporeSigma
All Photos(2)

Documents

203033

Sigma-Aldrich

Cesium iodide

99.999% trace metals basis

Synonym(s):

Caesium iodide, Caesium monoiodide

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
CsI
CAS Number:
Molecular Weight:
259.81
EC Number:
MDL number:
UNSPSC Code:
12352302
eCl@ss:
38100503
PubChem Substance ID:
NACRES:
NA.23

Quality Level

assay

99.999% trace metals basis

form

solid

impurities

≤15.0 ppm Trace Metal Analysis

mp

626 °C (lit.)

density

4.51 g/mL at 25 °C (lit.)

SMILES string

[I-].[Cs+]

InChI

1S/Cs.HI/h;1H/q+1;/p-1

InChI key

XQPRBTXUXXVTKB-UHFFFAOYSA-M

Looking for similar products? Visit Product Comparison Guide

Related Categories

Application

Cesium iodide can be used as precursor to synthesize lead-free perovskite material, Cs2NaBiI6 (CNBI). The CNBI is highly stable and finds application in the field of solar cells, LEDs, and lasers.

It can be used to prepare brightest red emitting Cs2HfI6 scintillator which is applicable in high resolution gamma spectroscopy.

It can also be used tosynthesize Cesium based nanocrystals for the detection of ionizingradiations.

Features and Benefits

  • High quantum efficiency
  • High stability to ambient air and gas environment
Frequently used in devices such as phosphor screens for medical imaging, scintillators, calorimeters and a variety of particle detectors.

pictograms

Health hazardEnvironment

signalword

Warning

Hazard Classifications

Aquatic Acute 1 - Repr. 2

Storage Class

13 - Non Combustible Solids

wgk_germany

WGK 2

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 8

1 of 8

Lead(II) iodide 99%

Sigma-Aldrich

211168

Lead(II) iodide

Lead(II) iodide 99.999% trace metals basis

Sigma-Aldrich

203602

Lead(II) iodide

Cesium bromide 99.9% trace metals basis

Sigma-Aldrich

202142

Cesium bromide

Methylammonium iodide 98%

Sigma-Aldrich

793493

Methylammonium iodide

Tin(II) iodide AnhydroBeads™, −10 mesh, 99.99% trace metals basis

Sigma-Aldrich

409308

Tin(II) iodide

Methylammonium iodide ≥99%, anhydrous

Sigma-Aldrich

901434

Methylammonium iodide

Nobuhiro Yasui et al.
Advanced materials (Deerfield Beach, Fla.), 24(40), 5464-5469 (2012-08-14)
Alkali halide systems that function as phase-separated scintillators (PSSs) with light-guiding properties are sucessfully created. Furthermore, it is the matrix phases of the PSSs which display the light-guiding properties. CsI-NaCl:Tl is a practical material pair because of its high pixel
Tetsuro Matsumoto et al.
Radiation protection dosimetry, 146(1-3), 92-95 (2011-04-29)
A small-sized thermal neutron detector based on a (6)Li-glass scintillator and a plastic optical fibre has been developed for precise measurement of the spatial distribution of thermal neutron fluence rate. This detector was tested in experiments performed using thermal neutrons.
K J Tielrooij et al.
The journal of physical chemistry. B, 115(43), 12638-12647 (2011-09-10)
We study the reorientation dynamics of water molecules around ions using terahertz dielectric relaxation spectroscopy and polarization-resolved femtosecond infrared pump-probe spectroscopy. The results are discussed in relation to the ion-specific Hofmeister series and the concomitant "structure-making" and "structure-breaking" effects of
Marco Bertolini et al.
Medical physics, 39(5), 2617-2627 (2012-05-09)
The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer
Melanie Freed et al.
Medical physics, 37(6), 2593-2605 (2010-07-17)
Accurate models of detector blur are crucial for performing meaningful optimizations of three-dimensional (3D) x-ray breast imaging systems as well as for developing reconstruction algorithms that faithfully reproduce the imaged object anatomy. So far, x-ray detector blur has either been

Articles

Colloidal quantum dots (CQDs) are semiconducting crystals of only a few nanometers (ca. 2–12 nm) coated with ligand/surfactant molecules to help prevent agglomeration.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service