D-910

Supelco

Diazepam-d5 solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
C16D5H8ClN2O
CAS Number:
Molecular Weight:
289.77
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material

Quality Level

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

drug control

Narcotic Licence Schedule B (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IV (Portugal)

concentration

1.0 mg/mL in methanol

technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

application(s)

clinical testing

format

single component solution

storage temp.

−20°C

SMILES string

O=C1CN=C(C2=C([2H])C([2H])=C([2H])C([2H])=C2[2H])C3=C(C=CC(Cl)=C3)N1C

InChI

1S/C16H13ClN2O/c1-19-14-8-7-12(17)9-13(14)16(18-10-15(19)20)11-5-3-2-4-6-11/h2-9H,10H2,1H3/i2D,3D,4D,5D,6D

InChI key

AAOVKJBEBIDNHE-VIQYUKPQSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Diazepam is a benzodiazepine used to treat a number of symptoms from anxiety and panic attacks to insomnia. This stable-labeled internal standard is suited for quantitation of diazepam levels in urine, serum, or plasma by LC/MS or GC/MS for urine drug testing, clinical toxicology, forensic analysis, or isotope dilution methods. Diazepam, a benzodiazpine frequently abused recreationally, is sold under the trade name Valium®.

Application


  • Diazepam-d₅ as an analytical standard: Diazepam-d₅ is widely used as a stable isotope-labeled standard in analytical research for accurate quantification of diazepam in biological samples. It ensures high precision in mass spectrometry analyses, crucial for both therapeutic monitoring and forensic investigations (Wagmann et al., 2020).

  • Internal standard in mass spectrometry: As an internal standard, Diazepam-d₅ provides consistency and accuracy in mass spectrometric quantification of drugs, aiding in the robust analysis required in pharmacokinetic studies and drug metabolism research. This application is essential for determining drug concentration and studying metabolic pathways in clinical pharmacology (Villain et al., 2004).

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany
Valium is a registered trademark of Roche Products Inc.

related product

Product No.
Description
Pricing

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

49.5 °F - closed cup

flash_point_c

9.7 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 7

1 of 7

Zolpidem-D6 solution 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Supelco

Z-001

Zolpidem-D6 solution

Alprazolam-d5 solution 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Supelco

A-902

Alprazolam-d5 solution

Codeine-D3 solution 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Supelco

C-007

Codeine-D3 solution

Diazepam

Sigma-Aldrich

D0899

Diazepam

Desmethyldiazepam analytical standard

Supelco

D7282

Desmethyldiazepam

Articles

This study compares the use of SPME LC Tips to dried blood spots (DBS) in terms of extraction efficiency and detection limits of target analytes from whole blood.

Comparative analysis of Supel™ BioSPME 96-Pin device with a rapid equilibrium dialysis technique for accuracy of measured values, sample cleanliness, and workflow time in drug protein binding.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service