1.05794
TLC plates, Silica gel 60 F₂₅₄
pkg of 100 plates, plate L × W 2.5 cm × 7.5 cm, glass support
Synonym(s):
Silica Gel 60 F₂₅₄ TLC Plates
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
material
glass support
silica gel 60 matrix
Quality Level
feature
binder Organic Polymer
fluorescent indicator
packaging
pkg of 100 plates
technique(s)
thin layer chromatography (TLC): suitable
layer thickness
250 μm
plate L × W
2.5 cm × 7.5 cm
particle size
10-12 μm
pore size
60 Å medium pore diameter
storage temp.
2-30°C
Related Categories
General description
100 Glass plates 2,5 x 7,5 cm
Application
- MSTFA as an Effective TMS Source for the TMSOTf-Catalyzed Synthesis of Cyclic Acetals: This study demonstrates the utility of 2,2,2-Trifluoro-N-methyl-N-(trimethylsilyl)acetamide as an effective trimethylsilyl donor in the synthesis of cyclic acetals, showcasing its role in facilitating catalyst efficiency and improving reaction conditions for organic synthesis within the realm of green chemistry practices (Radomkit et al., 2024).
Linkage
Replaces: 15341-1; 15341
Analysis Note
Specific surface area (according to BET; 5-Pt.measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm):0.74 - 0.84 ml/g
d 50 (laserdiffraction, size distribution): 9.7 - 11.7 µm
Layerthickness: 210 - 270 µm
Deviationof layer thickness per plate: ≤ 35 µm
Chromatographictesting:
A) colourtest
hRf-values
- bleu viforganol, lipophile: 11 - 25
- CeresBlack G, lipophile: 34 - 48
- ceresViolet brn, lipophile: 52 - 67
separationnumber (colour test, lipophile): ≥ 10.5
B)Steroid test
hRf-values
- Hydrocortisone, steroid test: 25 - 37
- Reichstein S, steroid test: 37 - 49
- Methyltestosterone, steroid test: 42 - 54
Typical value determined on a conditioned plate
Eluent A) Toluene (45% rel. humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel. humidity)
Pore volume(N₂-isotherm):0.74 - 0.84 ml/g
d 50 (laserdiffraction, size distribution): 9.7 - 11.7 µm
Layerthickness: 210 - 270 µm
Deviationof layer thickness per plate: ≤ 35 µm
Chromatographictesting:
A) colourtest
hRf-values
- bleu viforganol, lipophile: 11 - 25
- CeresBlack G, lipophile: 34 - 48
- ceresViolet brn, lipophile: 52 - 67
separationnumber (colour test, lipophile): ≥ 10.5
B)Steroid test
hRf-values
- Hydrocortisone, steroid test: 25 - 37
- Reichstein S, steroid test: 37 - 49
- Methyltestosterone, steroid test: 42 - 54
Typical value determined on a conditioned plate
Eluent A) Toluene (45% rel. humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel. humidity)
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service