Supelco

Micro particle size standard based on polystyrene monodisperse

size: 10.0 μm

Synonym(s):

Monodisperse polystyrene latex particles (10 μm), monodisperse polystyrene microbeads (10 μm), monodisperse polystyrene microspheres (10 μm), polystyrene monodisperse microparticles (10 μm), Size standards

Sign Into View Organizational & Contract Pricing


About This Item

MDL number:
UNSPSC Code:
41116107
NACRES:
NA.25

grade

analytical standard

Quality Level

form

aqueous suspension

crosslinking

2 % cross-linked

concentration

2% (solids)

particle size

10.0 μm std dev <0.15 μm, coeff var <1.5%

application(s)

glass & ceramic
industrial qc
pharmaceutical

format

neat

storage temp.

2-8°C

Looking for similar products? Visit Product Comparison Guide

General description

Monodisperse polystyrene based micro particles (size: 10 μm) are a particle size standard, ideal for characterizing particle size distribution (PSD) of test samples.

Application

Used to calibrate and validate the performance of particle sizing instruments.
Monodisperse polystyrene latex particles are also used to:
  • fabricate microsphere-based interferometric optical probe called reflectophore
  • validate the Airy Disc First Fringe (ADFF) analysis technique based on size measurements
  • qualify spectral reflectometry (SpeRe) instrument by using scanning electron microscopy (SEM)

Features and Benefits

  • suitable for routine instrument calibration checks, testing and corrections
  • available in 5 mL and 10 mL pack sizes as neat samples

Analysis Note

For every lot exact values of particle size and standard deviation are determined with an accuracy of 0.001 μm. The size determination of these particles follows procedures described by National Institute of Standards and Technology (NIST, USA) respectively by the Community Bureau of Reference (BCR), esp.:
  • Transmission electron microscopy (TEM)
  • Scanning electron microscope
  • Light microscopy
  • Coulter counter with MDF-system
Calibration of equipment is carried out with NIST-respectively BCR-particle size standards.

Legal Information

Coulter is a trademark of Beckman Coulter, Inc.

Storage Class

10 - Combustible liquids

wgk_germany

WGK 3

flash_point_f

410.0 °F

flash_point_c

210 °C

ppe

Eyeshields, Gloves


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Junhwan Kwon et al.
Nature communications, 8(1), 1832-1832 (2017-12-01)
In the mammalian nervous system, myelin provides electrical insulation for the neural circuit by forming a highly organized, multilayered thin film around the axon fibers. Here, we investigate the spectral reflectance from this subcellular nanostructure and devise a new label-free
Growth phenotype screening of Schizosaccharomyces pombe using a Lensless microscope
Penwill AL, et al.
Biosensors And Bioelectronics, 54(8), 345-350 (2014)
Yongjae Jo et al.
Nature communications, 9(1), 4577-4577 (2018-11-06)
Fluorescent optical probes have rapidly transformed our understanding of complex biological systems by providing specific information on biological targets in the natural living state. However, their utility is often limited by insufficient brightness, photostability, and multiplexing capacity. Here, we report
Singlet oxygen-mediated selective C--H bond hydroperoxidation of ethereal hydrocarbons
Sagadevan A, et al.
Nature Communications, 8(1), 1-8 (2017)

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service