23906

Supelco

OMI® Purifier Tube

OMI-2 Purifier Tube

Synonym(s):

OMI®-2 INDICATOR TUBE

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41115700

General description

OMI® purifier tubes simultaneously remove oxygen, water vapor, CO, CO2, most sulfur compounds, most halogen compounds, alcohols, phenols to less than 10ppb. They also purify helium, hydrogen, nitrogen, argon and methane. Color change indicates purifier exhaustion. Glass body does not diffuse air or off-gas. Furthermore, they are ideal for Hall, ECD and GC/MS detection systems.
The OMI is a polishing purifier that removes many contaminants that other upstream purifiers miss. It will simultaneously and irreversibly remove moisture, oxygen, carbon monoxide, carbon dioxide, most sulfur compounds, most halogen compounds, alcohols, and phenols to less than 10 ppb. It is recommended that an OMI be installed in carrier gas streams just upstream of every GC. It consists of two components:
  • A re-useable tube holder that is installed into the gas delivery system. The use of polycarbonate provides see-through capability along with safety.
  • A purifier tube containing an indicating resin (changes color from black to brown when exposed to as little as 1 ppm of moisture or oxygen). The use of glass provides see-through capability and prevents diffusion of room contaminants into the gas stream.

Spent purifier tubes are easily replaced. Simply unscrew the end assembly from the tube holder and replace it with a new purifier tube. The design prevents room air from entering the new tube during installation (protective foil covers on each end are only pierced as the end assembly is screwed back onto the tube holder to complete installation).

Note: This item requires a re-useable tube holder (purchased separately).

Footnote

First time users must order both a purifier tube and a reuseable holder (P/N 23921).

Legal Information

OMI is a registered trademark of Merck KGaA, Darmstadt, Germany

required but not provided

Product No.
Description
Pricing

pictograms

FlameCorrosion

signalword

Danger

Hazard Classifications

Eye Dam. 1 - Skin Corr. 1B - Water-react 1

supp_hazards

Storage Class

4.3 - Hazardous materials, which set free flammable gases upon contact with water

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 1

1 of 1

Articles

Nitrosamines have been discovered as a serious contaminant group in active pharmaceutical ingredients (API) belonging to the sartan family. This article describes a GC-MS method for the determination of nitrosamines in Valsartan tablets according to US FDA guide lines that can be used for pharma QC.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service