radiello Vertical Adapter

threaded for standard use, pk of 20

Sign Into View Organizational & Contract Pricing


About This Item

UNSPSC Code:
41104008
NACRES:
NB.24

packaging

pk of 20

manufacturer/tradename

Radiello Code 122

technique(s)

passive air sampling: suitable

application(s)

air monitoring
environmental
industrial hygiene

Looking for similar products? Visit Product Comparison Guide

General description

For personal sampling (breathing zone assessment) a vertical adapter is available to position the Radiello diffusive body vertically on the Radiello triangular support plate.

Legal Information

radiello is a trademark of Institi Clinici Scientifici Maugeri

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 8

1 of 8

radiello™ Diffusive Bodies yellow, configured for reduced sampling rates, pk of 20

RAD1202

radiello Diffusive Bodies

radiello™ On-Field Thermometer Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3

RAD126

radiello On-Field Thermometer

radiello™ Diffusive Bodies permeative, configured for anaesthetic gases and vapors, pk of 20

RAD1203

radiello Diffusive Bodies

radiello™ Cartridge Adsorbents for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20

RAD165

radiello Cartridge Adsorbents

radiello™ Filtration Kit pk of 20

RAD174

radiello Filtration Kit

radiello™ On-Field Thermometer Reader, pk of 1

RAD127

radiello On-Field Thermometer

radiello™ Cartridge Adsorbents for sampling Hydrogen Sulfide (H2S), matrix microporous PE coated with zinc acetate, pk of 20

RAD170

radiello Cartridge Adsorbents

radiello™ Cartridge Adsorbents for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20

RAD145

radiello Cartridge Adsorbents

J Dekeirsschieter et al.
Forensic science international, 189(1-3), 46-53 (2009-05-09)
Forensic entomology uses pig carcasses to surrogate human decomposition and to investigate the entomofaunal colonization. Insects communicate with their environment through the use of chemical mediators, which in the case of necrophagous insects, may consist in the cadaveric volatile organic
Armelle Vallat et al.
Phytochemistry, 66(13), 1540-1550 (2005-06-14)
Headspace volatiles from apple-bearing twigs were collected in the field with a Radiello sampler during three different diurnal periods over the complete fruit growing season. Analyses by thermal desorption-GC-MS identified a total of 62 compounds in changing quantities, including the
Benoît Oury et al.
Journal of occupational and environmental hygiene, 3(10), 547-557 (2006-08-16)
Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special
Rocco Rella et al.
The Science of the total environment, 487, 255-259 (2014-05-03)
The proofing treatment of the floor slabs with a solvent based material and successive treatment with epoxy resin resulted in significant air contamination in a primary school. The contamination caused illnesses in many occupants of school. The GC/MS investigations of
Anne Pennequin-Cardinal et al.
Talanta, 65(5), 1233-1240 (2008-10-31)
Radiello((R)) diffusive samplers filled with a thermally desorbable adsorbent (graphitised charcoal Carbograph 4) have been tested for the monitoring of BTEX. The sampling rates have been estimated under various controlled atmospheres in order to evaluate the effects of two factors

Articles

Cartridge RAD147 is a stainless steel net cylinder with 100 mesh grid opening and 4.8 mm diameter, packed with 250 ± 10 mg of Tenax-TA, particle size 20-35 mesh. Phenols are trapped by adsorption and recovered by thermal desorption, analysis is performed by capillary gas chromatography and MS detection.

radiello® Diffusive Air Sampling Application - Ammonia

radiello® Diffusive Air Sampling Application - Hydrogen Sulfide

Learn about radiello® Diffusive Sampling Aldehydes Applications & Methods.

Protocols

Protocol for radiello® Diffusive Air Sampling Application - Nitrogen and Sulfur Dioxide

Volatile organic compounds are trapped by adsorption and recovered by thermal desorption, analysis is performed by capillary gas chromatography and FID or MS detection.

The adsorbing cartridge is formed by a micropore polyethylene tube filled with silica gel coated with 4,4’-dipyridylethylene and closed, at one end, by a PTFE cap. Upon exposure, acid-catalysed ozonolysis of 4,4’-dipyridylethylene leads to 4-pyridylaldehyde.

Protocol for radiello® Diffusive Air Sampling Application - Anaesthetic Gases and Vapors

See All

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service