UFC203024
Amicon® Ultra Centrifugal Filter, 30 kDa MWCO
sample volume 2 mL, regenerated cellulose membrane, MWCO 30 kDa
Synonym(s):
Centrifugal concentrator, 30 kDa MWCO, 2 mL sample volume
About This Item
Recommended Products
material
polypropylene tube (for collection)
regenerated cellulose membrane
styrene-butadiene housing
Quality Level
sterility
non-sterile
product line
Amicon®
manufacturer/tradename
Amicon® Ultra
parameter
2 mL sample volume
technique(s)
protein extraction: suitable
protein purification: suitable
L
119.7 mm
diam.
15.9 mm
filtration area
1 cm2
pore size
30 kDa MWCO
shipped in
ambient
General description
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 50-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss. Efficient recovery of the concentrated sample (retained species) is achieved by a convenient reverse spin step after collecting the filtrate.
The device can be spun in a swinging bucket or fixed angle rotor. Amicon® Ultra-2 mL devices are supplied non-sterile and are for single use only. With their vertical membrane design and reverse spin, Amicon® Ultra 2 mL filters deliver the highest recovery with shortest spin times.
Application
- Ultrafiltration with 30,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates.
- Primer removal, PCR cleanup, removal of linkers or macromolecular labels from a reaction mix, and protein removal prior to HPLC.
- Desalting, buffer exchange and protein dialysis.
- Size exclusion and protein fractionation.
Features and Benefits
- Ultracel® regenerated cellulose membrane with 30 kDa NMWCO delivers retentate recovery of greater than 90%
- Concentrates 2 mL down to 15-70 μL
- 98% sample recovery
- Fast processing time: 10- to -30-minute spin times
- Engineered dead stop
- Reverse spin capability provides consistent recoveries
Linkage
Physical form
Legal Information
Still not finding the right product?
Give our Product Selector Tool a try.
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
This page discusses the principles and benefits of using ultrafiltration membranes in protein sample preparation. Possible applications include solvent exchange, protein sample concentration, or sample purification.
Related Content
Concentrate protein, don’t lose it. Recover protein reliably when you concentrate with Amicon® Ultra filters.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service